Description
Instructions & Datasheet
Specifications
| Item | Contents | Criteria | |
| 1 | Model | HCX-D345 | 10S- 40A working current |
| 2 | Voltage | Charging voltage | 42V |
| 3 | Current | Maximal continuous charging current | 40A |
| Maximal continuous discharging current | 40A | ||
| Current consumption | ≤50μA | ||
| 4 | Overcharge Protection | Over charge detection voltage | 4.28V +- 0.025 V |
| Over charge detection delay time | 0.5S~2S | ||
| Over charge release voltage | 4.08V +- 0.05 V | ||
| 5 | Over Discharge Protection | Over discharge detection voltage | 3.00V +- 0.05 V |
| Over discharge detection delay time | 50~200mS | ||
| Over discharge release voltage | 3.00V +- 0.1 V | ||
| 6 | Over Current Protection | Over current detection voltage | 0.1V~0.2V |
| Over current detection current | 100A +- 20A | ||
| Detection delay time | 5~20mS | ||
| Release condition | Cut load,automatically recover | ||
| 7 | Short Circuit Protection | Detection condition | Exterior shot circuit |
| Detection delay time | 200~500uS | ||
| Release condition | Cut load,automatically recover | ||
| 8 | Balance/Equilibrium | Balance voltage for single cell | 4.20V±0.025V |
| Balance current for single cell | 126mA±15mA | ||
| 9 | Resistance | Inner resistance | ≤20mΩ |
| 10 | Temperature | Operating temperature range | 0 ~+85°C |
| Storage temperature range | 0 ~+85°C | ||
| 11 | Size (L*W*T) | L145mm*W68mm*T16mm (13mm if move the sensor to the side) | |






Reviews